Product Description
Anaesthesia Workstation Machine provided by our company, is a medical device which is widely used to generate and mix a fresh gas flow of medical gases and inhalational anaesthetic agents for the purpose of inducing and maintaining anaesthesia. This machine is tested under various parameters to ensure its excellent working and effectiveness. Our Anaesthesia Workstation Machine is widely appreciated by our people, for its unique features and high performance too.This machine is very cost effective and can be easily purchased by our eminent clients at nominal prices, in bulk quantities.
SYSTEMA- 15
ANAESTHESIA MACHINE
KEY FEATURES:
- 3 gas system Hypoxic Guard-Oxygen, Air, Nitrous
- Ventilator with Dual Mode Adult & Paediatric
- Monitor with 5 multipara facilities
- Imported ISO Fluorine/ Savo Fluorine/ Halothane Vaporizer
- Circle Absorber System
- Extra Space with dual drawers soundless ball channel systems.
TECHNICAL SPECIFICATIONS:
Gas Rotameters :
MNLCP SYSTEMA 15 has 3 gases delivery system. Oxygen, Air, Nitrous. 3 Calibrated Rotameters (O2, Air, N2). It has Hypoxic guard system which deliver gases as per 3:1 Oxygen & Nitrous ratio.
Ventilator :
- Patient Type : Adult and Pediatric
- Tidal Volume : 50 to 1200 ml.
- Frequency : 8 to 40 BPM
- I : E Ratio : 1:1, 1:2, 1:3 and 1:4
- Mode of Operation : CMV, Manual
- Alarms Pressure : Low and High, Active patient, driving gas failure , low battery indication, circuit disconnect,
- Minute Volume : low and High
- Monitoring Parameters : Tidal Volume and Minute Volume
- Pressure Display : 10 to 90 mBar in LED graph
- High Pressure Limit : 20 to 60 mBar
- Low Pressure Limit : 90 to 20 mBar
- Power Input : 0 to 260 VAC 50/60 Hz
- Minute Volume High : 3 to 50 Liters
- Minute Volume Low : 0 to 47 Liters
- Driving Gas Input : 3 Bar Pressure
- Battery Backup : up to 2 Hours ( Lithium-ion )
Multipara Monitor :
- 6 Standard Parameters: ECG, RESP, NIBP, SPO2, 2-Temp, PR/HR.
- 8 high resolution colour TFT LCP display with touch screen.
- Real time S-T segment analysis, pace maker detection.
- Multi lead ECG wave forms display in phase
- Up to 2 hours working capacity of built in rechargeable battery
- Networking capacity
- Patients info input management function
- Capture dynamic waveforms.
- Efficient resistance to interference of defibrillator and HF knife.
- Large volume of tabular and graphic trends information storage and easy to recall.
Vaporizer :
- 5 Lpm O2 210C 20C
- Vaporiser 5% 0.25 of the delivered agent or 15% of the dial setting (whichever is greater)
- Vaporiser 8% 0.4 of the delivered agent or 15% of the dial setting (whichever is greater)
- Calibrated at sea level
Environmental Specification -
- Temperature 150C to 350C
- Humidity 30% to 75% relative humidity.
- Works consistently in altitudes upto 2440m above sea level
Performance Reliability -
- Performs with gas flow rates from 0.2 - 15 lpm
- Systems are Selectatec Compatible With Interlock & Cage mount (ISO 23mm tapers)
Types of Vaporizers - Isoflurane, Sevoflurane, Halothane, Enflurane. Can be fitted well.
Robust Construction for ReliabilityFashioned from high-grade stainless steel, the Anaesthesia Workstation Machine is designed for longevity and easy maintenance. Its sturdy build supports demanding applications in hospitals, clinics, and laboratories, ensuring ongoing performance and hygiene.
Versatile Usage Across Patient GroupsEngineered for both adult and pediatric care, the workstation adapts seamlessly to different patient requirements. Its carefully calibrated systems facilitate safe and accurate anaesthesia delivery regardless of patient age or size.
Trusted by Professionals Across IndiaDistributed, imported, and manufactured by reputable Indian suppliers, this machine is widely adopted in healthcare facilities nationwide. Supported by expert service providers and traders, users benefit from reliable installation, maintenance, and after-sales support.
FAQ's of Anaesthesia Workstation Machine:
Q: How is the Anaesthesia Workstation Machine used in hospital and clinical settings?
A: The machine is utilized to deliver precise doses of anaesthetic agents to adult and pediatric patients during surgical or diagnostic procedures. Its intuitive controls and robust monitoring systems support safe and efficient operation in hospitals, clinics, and laboratories.
Q: What are the key benefits of using a stainless steel anaesthesia workstation?
A: Stainless steel construction ensures durability, corrosion resistance, and easy sterilization, which are vital for maintaining hygiene and safety standards in medical environments.
Q: When should the Anaesthesia Workstation Machine be serviced?
A: Regular servicing should be conducted as recommended by the manufacturer or supplier, typically after a set number of uses or operational hours, to ensure optimal performance and patient safety.
Q: Where can I purchase or obtain service support for this machine in India?
A: You can acquire the Anaesthesia Workstation Machine from authorized distributors, importers, manufacturers, and suppliers across India. Service providers offer installation, training, and maintenance support as required.
Q: What is the process for setting up the workstation for different patient groups?
A: Setup involves calibrating the machine for either adult or pediatric use, selecting appropriate breathing circuits, and adjusting anaesthetic delivery settings based on patient profiles and surgical requirements.
Q: How can this machine benefit both adult and pediatric patient care?
A: The workstation's versatile design allows for safe, effective anaesthesia management across various ages, ensuring patients receive the appropriate care tailored to their physiological needs.